{"product_id":"neomed-polyurethane-feeding-tubes","title":"NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes","description":"\u003cdiv style=\"background: #f8f9fa; border-left: 4px solid #0057a8; padding: 12px 16px; margin-bottom: 20px;\" id=\"ai-summary\"\u003e\n\u003cstrong\u003eClinical Summary:\u003c\/strong\u003e NeoMed Polyurethane Enteral Feeding Tubes are single-use, sterile nasogastric\/orogastric tubes manufactured from medical-grade polyurethane with ENFit connectors conforming to ISO 80369-3. Available in 5 Fr, 6.5 Fr, and 8 Fr sizes with lengths of 40 cm, 60 cm, and 90 cm, these tubes feature a radiopaque stripe for radiographic placement verification, bold insertion depth markings, and an open distal tip with three offset portholes. They are indicated for short-to-medium-term enteral nutrition delivery in neonatal, paediatric, and adult patients, with a maximum indwell time of 30 days.\u003c\/div\u003e\n\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eNeoMed Polyurethane Enteral Feeding Tubes are precision-engineered medical devices designed for nasogastric (NG) and orogastric (OG) enteral nutrition delivery. Manufactured by Avanos Medical (formerly Halyard Health \/ Kimberly-Clark Health Care), the NeoMed product line represents a specialised enteral feeding system originally developed for the neonatal intensive care unit (NICU) and subsequently expanded for paediatric and adult applications. The tubes are fabricated from soft, medical-grade polyurethane — a material selected for its biocompatibility, flexibility at body temperature, and resistance to gastric acid degradation, enabling extended indwell times of up to 30 days without scheduled replacement.\u003c\/p\u003e\n\u003cp\u003eEach tube features the ENFit connector system, an international standard (ISO 80369-3) designed to prevent misconnection between enteral and non-enteral devices — a critical patient safety feature that eliminates the risk of accidental intravenous administration of enteral feeds. The tube incorporates a semi-encapsulated radiopaque stripe visible under fluoroscopy or X-ray for post-insertion placement verification, bold centimetre depth markings for accurate insertion depth documentation, and an open distal tip with three offset portholes designed to minimise occlusion and reduce bacterial colonisation risk. The plugged-style hub closure provides a sealed system between feeds, further reducing infection risk. NeoMed feeding tubes are available in French sizes and lengths suited to the full patient age spectrum, from premature neonates to adults.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" cellspacing=\"0\" cellpadding=\"8\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvanos Medical (NeoMed brand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnteral Feeding Tube — Nasogastric \/ Orogastric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMedical-grade polyurethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable French Sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Fr, 6.5 Fr, 8 Fr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Lengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 cm, 60 cm, 90 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENFit (ISO 80369-3 compliant) — anti-misconnection enteral connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRadiopacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSemi-encapsulated radiopaque stripe for fluoroscopic\/X-ray placement verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsertion Markings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBold centimetre depth markings along tube length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDistal Tip Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen tip with three offset lateral portholes — no hidden cavities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHub Closure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlugged-style sealed closure to reduce bacterial colonisation risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Indwell Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 30 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSterility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSterile; ethylene oxide (EO) sterilised; single use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLatex Content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLatex-free; DEHP-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended Population\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNeonatal, paediatric, and adult patients requiring nasogastric or orogastric enteral nutrition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegulatory \/ Quality\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFDA 510(k) cleared (Class II medical device); CE marked under MDR 2017\/745; manufactured under ISO 13485 quality management system; ISO 80369-3 ENFit connector compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividually packaged, sterile; available in cases of 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eClinical Indications and Key Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShort-to-medium-term enteral nutrition delivery (up to 30 days indwell) via nasogastric or orogastric route in neonatal intensive care units (NICU)\u003c\/li\u003e\n\u003cli\u003ePaediatric enteral feeding for patients unable to achieve adequate oral nutrition due to prematurity, congenital anomalies, or neurological conditions\u003c\/li\u003e\n\u003cli\u003eAdult nasogastric feeding in post-operative, critical care, and long-term care settings where oral intake is insufficient or contraindicated\u003c\/li\u003e\n\u003cli\u003eEnteral medication administration via nasogastric route using ENFit-compatible syringes\u003c\/li\u003e\n\u003cli\u003eGastric decompression and aspiration for pH testing to confirm tube placement (in conjunction with radiographic verification)\u003c\/li\u003e\n\u003cli\u003eTransitional enteral feeding in patients being weaned from parenteral nutrition to enteral nutrition pathways\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the ENFit connector and why is it important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ENFit is an internationally standardised enteral feeding connector defined by ISO 80369-3. It features a unique geometry that physically prevents connection to non-enteral devices such as intravenous (IV) lines, tracheostomy tubes, or Luer-lock syringes. This design eliminates the risk of enteral feed misconnection — a recognised patient safety hazard that has historically resulted in serious adverse events. The International Organization for Standardization (ISO) and the Global Enteral Device Supplier Association (GEDSA) mandate ENFit adoption for all new enteral feeding systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long can NeoMed polyurethane feeding tubes remain in situ?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: NeoMed polyurethane feeding tubes are rated for a maximum indwell time of up to 30 days, significantly longer than PVC feeding tubes (which typically require replacement every 5–7 days). The polyurethane material resists degradation from gastric acid and maintains flexibility at body temperature throughout the indwell period. This extended indwell time reduces the frequency of tube replacements, minimising patient discomfort and procedural risks, particularly in the neonatal and paediatric populations. Clinicians should follow institutional protocols and manufacturer guidelines for tube assessment and replacement scheduling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What French sizes and lengths are available, and how should size be selected?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: NeoMed feeding tubes are available in 5 Fr (for neonates and small infants), 6.5 Fr (for larger infants and small children), and 8 Fr (for older paediatric and adult patients), with lengths of 40 cm (neonatal), 60 cm (paediatric), and 90 cm (older paediatric\/adult). Size selection should be based on the patient's weight, age, and nasogastric distance measurement (nose-ear-xiphoid or nose-ear-mid-umbilicus method for neonates). The smallest effective French size should be used to minimise nasal and oesophageal trauma, consistent with the European Society for Clinical Nutrition and Metabolism (ESPEN) enteral nutrition guidelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can healthcare facilities in Singapore purchase NeoMed feeding tubes from EMIS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. EMIS (Essential Medical International Supplies Pte Ltd) is a Singapore-registered medical device distributor authorised to supply NeoMed enteral feeding products. Singapore hospitals, NICUs, paediatric wards, home enteral nutrition services, and long-term care facilities can procure NeoMed feeding tubes with GST-registered invoicing. Products comply with the Health Sciences Authority (HSA) Health Products Act requirements for Class B medical devices in Singapore. Contact EMIS for institutional pricing and supply arrangements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What regulatory approvals do NeoMed feeding tubes hold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: NeoMed Polyurethane Enteral Feeding Tubes hold FDA 510(k) clearance as Class II medical devices in the United States, CE marking under the European Medical Device Regulation (MDR 2017\/745), and are manufactured under an ISO 13485-certified quality management system. The ENFit connector system complies with ISO 80369-3 for enteral feeding device connectors. In Singapore, enteral feeding tubes are classified as Class B medical devices under the HSA regulatory framework and must be sourced from authorised distributors to ensure product authenticity and traceability.\u003c\/p\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes is an oral nutrition product available from EMIS+ (emis.asia) in Singapore, used to support nutritional intake as part of a suitable diet or care plan. It is not a medicine and should be used as directed on the label or by a healthcare professional.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How should NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes be used?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Follow the serving instructions on the packaging, or the advice of your doctor or dietitian — especially if it is being used to supplement the diet of someone who is unwell, recovering, or has specific nutritional needs.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes available without prescription in Singapore?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes is available from EMIS+ (emis.asia) without a prescription. For medically-directed nutrition support, follow the plan set by your doctor or dietitian.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Where can I buy NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes in Singapore?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"NeoMed Polyurethane Feeding Tubes Medical Grade Enteral Feeding Tubes is available from EMIS+ at emis.asia, Singapore's nurse-led medical and wellness supply store, with fast island-wide delivery. Bulk orders for clinics and care facilities are welcome — contact us at emis.asia\/pages\/contact.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"B. Braun","offers":[{"title":"5FR","offer_id":43239232077902,"sku":"SG-B-0706-NPF-5FR","price":25.0,"currency_code":"SGD","in_stock":false},{"title":"6.5FR","offer_id":43239232110670,"sku":"SG-B-0707-NPF-65","price":25.0,"currency_code":"SGD","in_stock":false},{"title":"8FR","offer_id":43239232143438,"sku":"SG-B-0708-NPF-8FR","price":25.0,"currency_code":"SGD","in_stock":false},{"title":"10FR","offer_id":43239232176206,"sku":"SG-B-0709-NPF-10F","price":25.0,"currency_code":"SGD","in_stock":false},{"title":"12FR","offer_id":43239232208974,"sku":"SG-B-0710-NPF-12F","price":25.0,"currency_code":"SGD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0613\/3763\/2846\/files\/NeoMed_Polyurethane_Feeding_Tubes.png?v=1766956447","url":"https:\/\/th.emis.asia\/en\/products\/neomed-polyurethane-feeding-tubes","provider":"EMIS+","version":"1.0","type":"link"}